제품소개

제품소개

I-7015

ㆍ▷ 6-channel RTD Input

ㆍ▷ 3-wire RTD Input with Lead Resistance Elimination 

ㆍ▷ High Resolution: 16-bit 

ㆍ▷ Individual Channel Configuration 

Manual

Features

▷ 6-channel RTD Input 
▷ 3-wire RTD Input with Lead Resistance Elimination 
▷ High Resolution: 16-bit 
▷ Individual Channel Configuration 
▷ Open Wire Detection 
▷ 4 kV ESD Protection 
▷ 4 kV EFT Protection 
▷ 3000 VDC Intra-module Isolation 
▷ Dual Watchdog 
▷ Wide Operating Temperature Range: -25 to +75°C

Specification & Introduction

Analog Input 
▷ Channels 6 
▷ Wiring 2/3-wire 
▷ Sensor Types Pt100, Pt1000, Ni120, Cu50, Cu100, Cu1000 
▷ Resolution 16-bit 
▷ Accuracy ±0.05% of FSR 
▷ Sampling Rate 12 Hz (Total) 
▷ Individual Channel Configuration Yes 
▷ Overvoltage Protection 120 VDC 
▷ Open Wire Detection Yes 
▷ 3-wire RTD Lead Resistance Elimination - NO
▷ Resistance Measurement 3.2 kΩ Max. 


▷ Models :  I-7015 
▷ Communication  - Interface RS-485 
▷ Bias Resistor No (Usually supplied by the RS-485 Master. Alternatively, add a tM-SG4 or SG-785.) 
▷ Format (N, 8, 1) (N, 8, 2) (E, 8, 1) (O, 8, 1) 
▷ Baud Rate 1200 to 115200 bps 
▷ Protocol DCON  
▷ Dual Watchdog Yes, Module (1.6 Seconds), Communication (Programmable) 

LED Indicator/Display 
▷ System LED Indicator Yes, 1 as Power/Communication Indicator 

Isolation 
▷ Intra-Module Isolation, Field-to-Logic 3000 VDC 

EMS Protection 
▷ ESD (IEC 61000-4-2) ±4 kV Contact for each Terminal 
▷ EFT (IEC 61000-4-4) ±4 kV for Power Line 
 
Power 
▷ Reverse Polarity Protection Yes 
▷ Input Range +10 ~ +30 VDC 
▷ Consumption 1.1 W 

Mechanical 
▷ Dimensions (L x W x H) 123 mm x 72 mm x 35 mm 
▷ Installation DIN-Rail or Wall Mounting 

Environment 
▷ Operating Temperature -25 to +75°C 
▷ Storage Temperature -40 to +85°C 
▷ Humidity 10 to 95% RH, Non-condensing 
Ordering Information